17
Automatic exit loop
lead in wires are
twisted approx. 6
twists per foot.
Reverse loop lead in
wires are twisted
approx. 6 twists per
foot and are wired in
series.
Shadow loop lead in
wires are twisted
approx. 6 twists per
foot.
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Reverse
Reverse
Automatic Exit
Shadow
2.4 Loop Detector Wiring
If other detectors are used, use a separate power
supply to power these detectors.
Loop layout shown is for a typical swing gate
application with two-way traffic, or one-way exit
only traffic.
Refer to the Loop Information Manual (available
from www.dkaccess.com) for more information
on loops and loop detectors.
Loops and loop detectors MUST be installed with this gate
operator to help prevent the gate from accidentally closing
on vehicular traffic.
Loop detector wiring is shown for DoorKing plug-in loop
detectors only. If other loop detectors are used, refer to
the installation instructions supplied with those detectors
for wiring instructions.
Com
9410
9409
N.O.
1
1
ON
2 3 4 5 6 7 8
SW 1
Note: SW 1,
switches 5,
7 and 8
must be
OFF.
Note: Relay
must be set
to N.O.
Shadow Loop Output
NC
NO
6500-065-K-7-08