DKS Enterprises 6500 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Ouvreur de porte DKS Enterprises 6500. DKS Enterprises 6500 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Series 6500
Owner’s Manual
Series 6500
Vehicular Swing Gate Operator
Copyright 2008 DoorKing, Inc. All rights reserved.
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - Owner’s Manual

Series 6500Owner’s ManualSeries 6500Vehicular Swing Gate OperatorCopyright 2008 DoorKing, Inc. All rights reserved.

Page 2

86500-065-K-7-08Swing Gate RequirementsThe operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a

Page 3 - SPECIFICATIONS

9 96500-065-K-7-08Swing Gate ProtectionNon-contact SensorReverse LoopShadow LoopAutomatic Exit LoopCDDCMinimizes the potential of the gate closing whe

Page 4 - SECTION 2 - WIRING 14

106500-065-K-7-08SECTION 1 - INSTALLATIONPrior to beginning the installation of the swing gate operator, we suggest that you become familiar with the

Page 5 - SECTION 3 - ADJUSTMENTS 22

116500-065-K-7-08Space Gained from Standard Compact Installation 22” 28” 22” 28”Standard InstallationOperator Installation1.3 Type of InstallationsRec

Page 6 - Important Safety Instructions

22” 28” 22” 28”Concrete Pad LocationOperator Installation 42” 23”2”90° Plus Installation requires the Standard Compact Installation’s concrete pad to

Page 7 - Important Notices

136500-065-K-7-08Gate BracketCrank ArmControl ArmRelease hub with release tool. DO NOT REMOVE HUB!Bolt crank arm to operator.Slide elbow assembly on c

Page 8 - UL325 Entrapment Protection

146500-065-K-7-081.6 Determining Arm LengthsSlide elbow assembly back and fourth, manually opening and closing gate until satisfied with the gate’s 90

Page 9 - Glossary

15ChassisGroundElectrical BoxKnock-outsConduitNeutral115 VAC115 VAC ModelsElectrical BoxKnock-outsConduit230/460 VAC230/460 VAC115 VAC Neu115 VAC Neu1

Page 10 - Swing Gate Requirements

166500-065-K-7-082.3 Control WiringRadio Receiver power only. Power is limited to 250 ma.Open direction non-contact sensor. Stops the gate in the open

Page 11 - Swing Gate Protection

17Automatic exit loop lead in wires are twisted approx. 6 twists per foot.Reverse loop lead in wires are twisted approx. 6 twists per foot and are wir

Page 13 - Standard Compact Installation

186500-065-K-7-082.5 Auxiliary Device Wiring2019181716151413121110987654321The Remote Alarm Reset Station (Model 1404-080) MUST be mounted in the line

Page 14 - Compact Installation

19192.6 Primary / Secondary (Dual) Gate Connection1Motor2Motor3Neutral424VAC5Limit6Spare7Limit8COM1Motor2Motor3Neutral424VAC5Limit6Spare7Limit8COMCond

Page 15 - DO NOT REMOVE HUB!

206500-065-K-7-082.7 Main Terminal Description20191817161514131211109876543211. LOW VOLTAGE COMMON2. RADIO RELAY (SINGLE BUTTON) ACTIVATION3. 24 VA

Page 16 - SECTION 2 - WIRING

211Motor2Motor3Neutral424VAC5Limit6Spare7Limit8COM2.8 Auxiliary Terminal Description2.9 Second Terminal Description109876543211. OPEN DIRECTION NON-CO

Page 17 - 2.1 High Voltage Wire Runs

226500-065-K-7-083.1 Circuit Board AdjustmentsSECTION 3 - ADJUSTMENTSThe switch settings and adjustments in this chapter should be made after your ins

Page 18 - 2.3 Control Wiring

233.2 DIP-Switch SettingsThe two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on

Page 19 - 2.4 Loop Detector Wiring

246500-065-K-7-08Safety Protection13141211109876543213.4 Inherent Entrapment Sensing Adjustment3.3 Limit Sensing System AdjustmentThis vehicular gate

Page 20 - 2.5 Auxiliary Device Wiring

256500-065-K-7-08SECTION 4 - OPERATING INSTRUCTIONSWARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Neve

Page 21 - Interconnection Cable Wiring

266500-065-K-7-084.2 Shutdown ConditionsUnder various entrapment conditions the operator will assume either a soft or hard (alarm) shutdown. To determ

Page 22 - 2.7 Main Terminal Description

276500-065-K-7-084.3 Manual Gate OperationThis operator is equipped with a manual release system that will allow the gate to be pushed open in the eve

Page 23 - 6500-065-K-7-08

Class of Operation Model 6500 - UL325 Class I, II, III, IV Type of Gate Vehicular Swing Gates Only Horsepower 1/2 or 1 HP Voltage / Phase 115 VAC

Page 24 - SECTION 3 - ADJUSTMENTS

• Be sure that power is removed or shut-off prior to placing the gate operator in manual operation.Manual ReleaseRemove release tool andplace where s

Page 25 - 3.2 DIP-Switch Settings

296500-065-K-7-08SECTION 5 - OPTIONAL CONVENIENCE OPEN ADJUSTMENTSThe optional convenience open system installed in your vehicular gate operator is de

Page 26 - Entrapment Protection

306500-065-K-7-08DC MOTOR NEGATIVE OUTPUTDC MOTOR POSITIVE OUTPUTBATTERY NEGATIVE INPUTBATTERY POSITIVE INPUT24 VAC COMMON24 VAC INPUTACTIVATION OUTPU

Page 27 - 4.1 Power and Reset Switches

316500-065-K-7-086.1 MaintenanceSECTION 6 - MAINTENANCE AND TROUBLESHOOTINGInspection and service of this gate operator by a qualified technician shou

Page 28 - 4.2 Shutdown Conditions

326500-065-K-7-086.2 TroubleshootingHave a good VOM meter to check voltages and continuity. A Meg-Ohm meter capable of checking up to 500 meg-ohms of

Page 29 - 4.3 Manual Gate Operation

336500-065-K-7-08• Check the reversing sensitivity.• Disconnect the gate from the gate operator and check that the gate swings freely without any

Page 30

346500-065-K-7-086.4 Accessory ItemsThe following accessory items are available for the model 6500 swing gate operator.Contact Sensors - For use as a

Page 31 - 5.1 Operating Mode

356500-065-K-7-0820191817161514131211109876543211ON2 3 4 1ONREVERSELOOPP2EXITLOOPSELFTESTNCTIMEDELAYNOREV SENSEPRIMARYREV SENSESECONDARY12345678913121

Page 32 - 5.2 DC System Description

366500-065-K-7-082340OrangeSecondaryCurrentSensor2 Loops2019181716151413121110987654321––++1ON2 3 4 1ONREVERSELOOPP2EXITLOOPSELFTESTNCTIMEDELAYNOREV S

Page 33 - 6.1 Maintenance

376500-065-K-7-08SecondaryCurrentSensor2 LoopsModel 6500 1/2 HP 230 / 460 VAC20191817161514131211109876543211ON2 3 4 1ONREVERSELOOPP2EXITLOOPSELFTESTN

Page 34 - 6.2 Troubleshooting

26500-065-K-7-08SPECIFICATIONS 1SECTION 1 - INSTALLATION 10SECTION 2 - WIRING 14Gate ConstructionImportant Safety InstructionsInstructions regarding i

Page 35 - Symptom Possible Solution(s)

386500-065-K-7-082340Orange––++Batteries12 V3 Amp/Hr12 V3 Amp/Hr20191817161514131211109876543211ON2 3 4 1ONREVERSELOOPP2EXITLOOPSELFTESTNCTIMEDELAYNOR

Page 36 - 6.3 Built-in Diagnostics

396500-065-K-7-08SecondaryCurrentSensor20191817161514131211109876543211ON2 3 4 1ONREVERSELOOPP2EXITLOOPSELFTESTNCTIMEDELAYNOREV SENSEPRIMARYREV SENSES

Page 37 - Current Sensor

406500-065-K-7-082340Orange1 Loop––++Batteries12 V3 Amp/Hr12 V3 Amp/HrRedBlueWhite20191817161514131211109876543211ON2 3 4 1ONREVERSELOOPP2EXITLOOPSELF

Page 38

416500-065-K-7-08SecondaryCurrentSensor1 HPRedBlueWhiteGroundModel 6500 1 HP 230 / 460 VAC20191817161514131211109876543211ON2 3 4 1ONREVERSELOOPP2EXIT

Page 39

426500-065-K-7-0823401 LoopBrownSecondaryCurrent Sensor––++Batteries12 V3 Amp/Hr12 V3 Amp/HrModel 6500 1 HP 230 / 460 VAC / Convenience Open1 HPRedBlu

Page 40

436500-065-K-7-082340Model 6500 1/2 HP Secondary OperatorModel 6500 1/2 HP Secondary Operator/Convenience Open––++MagneticOpenSensor1/2 HP50uf Capacit

Page 41

446500-065-K-7-082340Model 6500 1 HP Secondary OperatorModel 6500 1 HP Secondary Operator/Convenience Open––++MagneticOpenSensor1 HPDC PowerBatteriesR

Page 43

6500-065-K-7-08DoorKing, Inc.120 Glasgow AvenueInglewood, California 90301U.S.A. Phone: 310-645-0023Fax: 310-641-1586www.doorking.comSeries 6500Owner’

Page 44

36500-065-K-7-08SECTION 3 - ADJUSTMENTS 22SECTION 4 - OPERATING INSTRUCTIONS 25SECTION 6 - MAINTENANCE AND TROUBLESHOOTING 3121212.8 Auxiliary Termin

Page 45

46500-065-K-7-08Gate ConstructionInstructions regarding intended installation:Vehicular gates should be constructed and installed in accordance with A

Page 46

5 56500-065-K-7-08• For gate operators utilizing contact sensors: 1. One or more contact sensors shall be located where the risk of entrapment or o

Page 47

66500-065-K-7-086UL325 Entrapment ProtectionClass IClass I and IIClass IIIClass IVClass IIClass III Class IVA vehicular gate operator (or system) inte

Page 48 - Inglewood, California 90301

7 76500-065-K-7-08GlossaryGATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage

Commentaires sur ces manuels